The fastest way to map corrosion in reinforced concrete
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500 The most complete half-cell solution for rapid on-site mapping of corrosion potential
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500
PM8500

Profometer Corrosion Potential

PM8500

The most complete half-cell solution for rapid on-site mapping of corrosion potential

  • World's fastest data acquisition using our unique wheel electrodes
  • Unmatched capabilities with real-time data analytics and visualization
  • Light and wireless sensor for comfortable measurements

Applications:

Identifying areas of corrosion in reinforced concrete structures / Estimation of corrosion potential of rebars / Estimation of concrete durability / Investigation of structural failures / Evaluation of effectiveness of corrosion repairs

Advanced software for on-site corrosion likelihood analysis, connected to the most compact sensor and unique wheel electrodes for the fastest area scanning
https://screeningeagleassets.s3.eu-central-1.amazonaws.com/asset/media/Brand/New%20Web%20Icons/Web%20Icons_21-10-20_Productivity-10.svg
Productivity
Boost your productivity up to 40 times faster than any other rod electrode on the market using our unique wheel electrodes
https://screeningeagleassets.s3.eu-central-1.amazonaws.com/asset/media/Brand/New%20Web%20Icons/web-icons-ergonomics.svg
Ergonomics
Compact, ultra-light and wireless for comfortable measurements in all types of concrete elements
https://screeningeagleassets.s3.eu-central-1.amazonaws.com/asset/media/Brand/New%20Web%20Icons/web-icons-on-site-data.svg
Onsite Data
Best-in-class app for corrosion assessment with several views for easy data evaluation and interpretation
Profometer App Corrosion
Elevate your corrosion assessment to the next level
  • Regular updates & releases
  • Customer-centric development
  • Unparalleled features to optimize workflow

Identify areas of corrosion likelihood in reinforced concrete elements effortlessly and reliably using the half-cell potential method. Get insightful 2D imaging, heatmaps and advanced stats for reporting and collaboration anywhere at anytime.

Collect reliable data to inform decision-making and ensure the longevity of the structure.

This intelligent, feature-rich app gets better and better over time, so you always have access to continuous innovation and over-the-air updates.

  • Regular updates & releases
  • Customer-centric development
  • Unparalleled features to optimize workflow

Identify areas of corrosion likelihood in reinforced concrete elements effortlessly and reliably using the half-cell potential method. Get insightful 2D imaging, heatmaps and advanced stats for reporting and collaboration anywhere at anytime.

Collect reliable data to inform decision-making and ensure the longevity of the structure.

This intelligent, feature-rich app gets better and better over time, so you always have access to continuous innovation and over-the-air updates.

Profometer App Corrosion
App Version 2

Say hello to Corrosion Mapping!

This second release provides great features to users of Profometer Corrosion PM8500.

Top capabilities introduced with App Version 2:

  • Corrosion Half-Cell Potential scans are now possible
  • Spot Scan and Area Scan for mapping small and big elements
  • Autosave Mode for quicker spot scans
  • Skipping cells, a fixed distance, and lines, optimizing the workflow for data acquisition
  • Deleting and overwriting data, optimizing the flexibility of data collection
  • Pause, stop, resume, and start measurements at any time, for more freedom
  • Flexible and fixed grid, for easier measurements
  • Basic and Expert Mode for creating different types of graphs
  • Creating photo, audio, and written comments for better insights
  • Real-time web-based data for safe storage, exporting and instant collaboration
  • Other features: Ambient temperature correction, Calibration of length, Custom gradient maps with flexible colour palette

 

... and much more.

 

Continuous software service, maintenance and bug fixes. Compatibility upgrades to fully support the latest generation iPads and the latest version of iOS to enhance your productivity.

 

Say hello to Corrosion Mapping!

This second release provides great features to users of Profometer Corrosion PM8500.

Top capabilities introduced with App Version 2:

  • Corrosion Half-Cell Potential scans are now possible
  • Spot Scan and Area Scan for mapping small and big elements
  • Autosave Mode for quicker spot scans
  • Skipping cells, a fixed distance, and lines, optimizing the workflow for data acquisition
  • Deleting and overwriting data, optimizing the flexibility of data collection
  • Pause, stop, resume, and start measurements at any time, for more freedom
  • Flexible and fixed grid, for easier measurements
  • Basic and Expert Mode for creating different types of graphs
  • Creating photo, audio, and written comments for better insights
  • Real-time web-based data for safe storage, exporting and instant collaboration
  • Other features: Ambient temperature correction, Calibration of length, Custom gradient maps with flexible colour palette

 

... and much more.

 

Continuous software service, maintenance and bug fixes. Compatibility upgrades to fully support the latest generation iPads and the latest version of iOS to enhance your productivity.

 


SWISS MADE_horizontal lockup.svg
Software for Profometer App Corrosion
Profometer App Corrosion
Tech Specs
Display Unit
Any compatible Apple iPad (iOS 11.0 and higher)

Measurement Modes
• Basic Mode
• Expert Mode
• Spot Scan (rod electrode)
• Line Scan (wheel electrode)
• Area Scan (wheel electrode)
• Fixed Grid (rod electrode)
• Flexible and Variable Grid (Wheel electrodes)
• Autosave mode (rod electrode)
• Grid set up (Origin of coordinates; Grid size; Cell size; Direction of measurement; Pattern of measurement)
• Delete and overwriting information (Cells; Lines; Whole scan)
Skipping data (Cells; Lines; Fixed distance)
• Pause and resume
• Stop and start

Review Modes
• Potential View for displaying a heat map with the potential values
• Statistic View - distribution and cumulative graph
• Chipping graph view for displaying the corroder areas based on the analysis

Advanced Features
• Support for copper, silver, mercury and SCE calomel electrodes
• Temperature correction
• Zoom in and out

Calibration Features
• Calibration of length

On-site annotations
• Markers - comments and voice notes
• Photos
• Geolocation

Reporting
• Cloud connectivity
• Workspace integration
• Share via URL
• Automatic Logbook
• Raw data export
• Instant report generation

Export formats
• JPG (Screenshot)
• PNG
• CSV
• HTML

Display Unit Specs*:
• Latest Apple® iPad recommended (iPad with iOS 11.0 and higher)
• Screen size: From 7.9" to 12.9"
• Resolution: Up to 2732-by-2048
• Memory: Up to 2TB
• Weight: Down to 301 g / 10.6 oz
• Camera: Up to 12MP Wide and 10MP Ultra Wide
• Optional: USB-C, 5G, Face ID

Display Unit Sensors*:
• LiDAR Scanner (optional)
• Three-axis gyro
• Accelerometer
• Ambient light sensor
• Barometer
• Built-in GPS/GNSS

* Depending on iPad model iPad is a trademark of Apple Inc.; iOS is a registered trademark of Cisco in the US and is used by Apple under license

PM8500 Tech Specs
Instrument
Tech Specs
Technology
Half Cell Potential

Measured Quantity
Corrosion potential in milivolts [mV]

Connection
Wireless - Bluetooth

Cover Measuring depth
First rebar layer

Voltage Measurement Range
-3000mV to +3000mV

Resolution
+-1mV

Input Impedance
100MOhm

Encoder Accuracy
+/- 0.5 mm / 0.02 in + 0.78% of measured length
Resolution: 3.3 mm / 0.13 in
(128 steps / rotation)

Max Scanning Speed
1 m/s - 3.3 ft/s

Max Area Scan
50 x 50 m - 165 x 165 ft

Dimensions
Sensor unit
(127 x 59 x 56)mm / (5 x 2.3 x 2.2)in without holder
(127 x 98 x 72)mm / (5 x 3.9 x 2.8)in with holder

Rod electrode
D= 36mm x 155mm / D=1.4 in x 6.1in with protection-cap

One wheel electrode
(194 x 138 x 127)mm / (7.6 x 5.4 x 5)in without telescopic rod
(2000 x 138 x 127)mm / (78.7 x 5.4 x 5)in with extended telescopic rod
(700 x 138 x 127)mm / (27.6 x 5.4 x 5)in with pulled in telescopic rod

Four wheel electrode
(830 x 350 x 140)mm / (32.6 x 13.8 x 5.5)in without telescopic rod
(2150 x 830 x 140)mm / (84.6 x 32.6 x 5.5)in with extended telescopic rod
(840 x 830 x 140)mm / (32.8 x 32.6 x 5.5)in with pulled in telescopic rod

Weight
Sensor unit
150g / 0.33 lbs without holder
220g / 0.49 lbs with holder

Rod electrode
120g / 0.26 lbs without cable / without cupper sulfate, without Interface-Box

One wheel electrode
2000g / 4.41 lbs without fluid, with interfacebox an telescopic rod
+ 435g / 0.96 lbs including fluid

Four wheel electrode
6900g / 15.2 lbs without fluid
+ 435g / 0.96 lbs per wheel including fluid

Standard kit (all items including carrying case)
7400g / 16.3 lbs

One wheel kit (all items including cartoon box)
2900g / 6.39 lbs

Four wheel kit (all items including carrying case)
17660g / 38.93 lbs

Battery
1xAA (NiMH) rechargeable or non rechargeable
Removable
Flight-safe
8 Hours autonomy
USB-C charger

Environmental Conditions
Humidity <95% RH, non-condensing
Operating temperature: -10ºC to +50ºC
Other customers also purchased:

Our Accessories
39260330
Ball joint for one-wheel electrode
MicrosoftTeams-image (263).png
Ball joint for one-wheel electrode
Ball joint accessory for the one-wheel electrode to connect to the telescopic rod for more flexible measurements.
Standards & Guidelines

Standards

  • Arrow, click names to download Standards & Guidelines ASTM C 876-15
  • Arrow, click names to download Standards & Guidelines DGZfP B3
  • Arrow, click names to download Standards & Guidelines JGJ/T 152 ( China )
  • Arrow, click names to download Standards & Guidelines JSCE E 601
  • Arrow, click names to download Standards & Guidelines RILEM TC 154-EMC
  • Arrow, click names to download Standards & Guidelines SIA 2006 ( Switzerland )
  • Arrow, click names to download Standards & Guidelines UNI 10174
  • Arrow, click names to download Standards & Guidelines ОДМ 218.3.001-2010
FAQ

How does Profometer Corrosion PM8500 work?

The Profometer Corrosion PM8500 is based on a technology called "Half Cell Potential". It works by measuring the electrochemical potential difference between a reference electrode and a rebar embedded in the concrete. This...

See More

What are the benefits of using Profometer Corrosion PM8500?

Using the PM8500 provides fast and accurate information about the corrosion potential of reinforced concrete structures. It can help you save money by identifying and mitigating corrosion damage before it becomes...

See More

What are the advantages of using Half Cell Potential to measure concrete corrosion probability?

Some advantages of using Half Cell Potential to measure concrete corrosion probability are:

  • Non-destructive test: Only a ground cable needs to be connected to a rebar, the electrical continuity of the rebar mesh needs...
See More

What is the sampling rate of the Profometer PM8500?

The sampling rate of the Profometer PM8500 is 900Hz.


How is the reference electrode selected for use in a half cell potential corrosion tester?

The reference electrode used in a half cell potential corrosion tester is selected based on the specific application and environment being tested. The PM8500 includes a copper/copper (Cu/CuSO4) reference electrode, but...

See More

What factors can affect the accuracy of a half cell potential corrosion test?

Factors that can affect the accuracy of a half cell potential corrosion test include the selection of the reference electrode, the quality of the electrolyte solution, the preparation of the concrete surface being tested,...

See More

How do moisture and temperature affects the readings?

Moisture can have a large effect of the measured potential leading to more negative values. High temperature causes concrete resistivity to be lower, which leads to more negative potentials, while low temperature causes...

See More

How does the concrete cover influence the corrosion inspection results?

The potential becomes more positive with increasing concrete cover. Very low concrete cover can lead to more negative potentials, which may indicate higher levels of corrosion. It is recommended to measure the concrete...

See More

How do I connect to a rebar?

We always recommend using Profometer PM8000 or GP8x00 to locate the rebar. Once the rebar is located, drill the concrete cover and connect the ground cable to it. The connection should be tested for electrical continuity,...

See More

Do I need to pre-wet the concrete surface before the testing?

The contact between the pore solution of the concrete and the probe can be impaired by a dried out concrete skin. This can greatly increase the electrical resistivity of the concrete.

It is recommended to moisten the...

See More

Can I have more information about what type of surface can be tested (coated, uncoated), how to do maintenance and cleaning of the electrodes, or any other valuable information?

Please, refer and download the Quick Start Guide and the Quick Reference Guide available under the "Download" section of the Profometer PM8500 page.


Loading…
Loading the web debug toolbar…
Attempt #