Dans la perspective d'un avenir alimenté par l'IA, nous utilisons des traductions par apprentissage automatique sur ce site web.

Infrastructure et actifs Inspection des structures en béton

Description de l'article

leadmagnet

Newsletter

Get the best NDT and InspectionTech content delivered straight to your inbox

Title

Non-destructive testing on the Huntingdon Railway Viaduct

Title

The Proceq GP8800 GPR being used to locate the post-tension ducts

Title

The Pundit PD8050 being used to detect hidden voids in the concrete.

Title

GPR Scan with Proceq GP8800 showing the path of the PT duct.

Title

Radargram view showing double reinforcing bars above the PT duct (apart from the last 2 bars on the right.)

Title

Results from the PD8050 showing localised voiding, taken over the same location as the GPR scans. Additionally the double rebars appear to have voiding around them.

Title

Air voiding as shown with Pundit PI8000 ultrasonic impact echo techonology, taken in the same spot as the PD8050.

Title

Augmented reality representation of the void taken with the Pundit PD8050 ultrasonic pulse echo technology.

Title

3D scan showing incorrectly placed reinforcing steel

Title

GPR Data displayed on the iPad revealing an incorrectly placed transverse reinforcing steel.

Title

Augmented reality view of the GPR data results showing the rebar configuration with missing horizontal rebar at the top.

Title

3D view showing PT Ducts sitting under location of missing horizontal reinforcement

Title

The red areas indicate where air is present within the duct using UPE technology.

Title

A 3D scan of the test area shown above appears to show voiding of a PT duct.